1. How the conduit pipes are specified?
A  Length in metre
B  Wall thickness in mm
C  Inner diameter in mm
D  Outer diameter in mm

2. What is the fusing factor for rewireable fuse?
A  1.1
B  1.4
C  2.1
D  2.5

3. What is the purpose of underwriter’s knot for pendent holder connection?
A  Avoid loose connections
B  Increase mechanical strength
C  Prevent excessive cap cover pressure
D  Reduce the strain from the terminals of accessories

4. What is the type of fuse?

A  Knife edge cartridge fuse
B  High rupturing capacity fuse
C  Ferrule contact cartridge fuse
D  Diazed screw type cartridge fuse

5. What is the name of electrical accessory?
A  Bracket holder
B  Edison screw type holder
C  Angle swivel lamp holder
D  Goliath Edison screw lamp holder  

6. What is the name of symbol used in wiring circuit?
A  Link
B  Fuse
C  Pull switch
D  Plug and socket

7. Which type of load is protected by the L-series MCB?

A  Motors
B  Geyser
C  Hand tools
D  Air conditioner

8. Which type of switch is used in the circuit?
A  One-way switch
B  Two-way switch
C  Intermediate switch
D  Multiposition switch

9. What is the effect of low current rated cable used to connect higher current load?

A  Voltage drop increases
B  Load current increases
C  Voltage drop decreases
D  Cable damage due to heat

10. What is the name of the conduit accessory?
A  Solid bend
B  Solid elbow
C  Inspection Bend
D  Inspection elbow

11. How many two way switches with intermediate switch are used to control one lamp from three different places?

A  1
B  2
C  3
D  4

12. What is the advantage of concealed wiring?

A  Easy to maintain
B  Less voltage drop
C  High insulation resistance
D  Protection against moisture

13. What is the name of the diagram?
A  Installation plan
B  Layout diagram
C  Wiring diagram
D  Circuit diagram

14. What is the fusing factor for high repturing capacity fuses (HRC)?

A  1.0
B  1.1
C  1.4
D  1.7

15. Which type of relay can be operated at both A.C and D.C?
A  Ferred relay
B  Thermal relay
C  Impulse relay
D  Dry reed relay

16. What is the name of the accessory used in electrical appliances?
A  2 Pin plug
B  Three pin plug
C  Iron connector with direct entry
D  Flat connector with side entry

17. What is the name of the accessory symbol?
A  Bell push switch
B  Two way switch
C  One way switch two poles
D  Multi position switch single pole

18. What is the purpose of the flexible cords in domestic wiring?

A  Concealed wiring
B  Permanent connection
C  Run cable through holes in ceiling
D  Connection transportable appliances

19. Which type of circuit breaker is used above 100 A current rating?
A  Miniature Circuit Breaker (MCB)
B  Earth Leakage Circuit Breaker (ELCB)
C  Moulded Case Circuit Breaker (MCCB)
D  Residual Current Circuit Breaker (RCCB)

20. What is the purpose of tin coating on copper fuse wire?

A  Withstand high temperature
B  Increase the fusing factor
C  Prevent oxidation of copper wire
D  Increase the mechanical strength

21. What is the name of the four insulated conductors group?

A  Pair
B  Core
C  Quad
D  Layer

22. How many two way switches are required in godown wiring circuit to control four lamps?

A  2
B  3
C  4
D  5

23. Why tree system of wiring most suitable for multistoryed building?
A  Easy load balancing
B  Constant voltage distribution
C  Offers minimum voltage drop
D  Easy in fault finding with many fuses

24. Which is used as a filler material for fixing screw hole on ceiling?
A  Paper
B  Nylon
C  Cement
D  Poly vinyl chloride

25. What is the symbol indicates?
A  Table fan
B  Ceiling fan
C  Bracket fan
D  Exhaust fan

26. What is the name of the relay?
A  Impulse relay
B  Dry reed relay
C  Electromagnetic relay
D  Mercury wetted contact relay

27. What is the name of the diagram?
A  Layout plan
B  Wiring diagram
C  Installation plan
D  Schematic diagram

28. Where the Iron Clad Double Pole (ICDP) main switch is used?
A  Large industrial installations
B  Control main or branch circuits
C  Single phase domestic installations
D  Three phase power circuit installations

29. Which electrical accessory belongs to general classification of accessories?
A  Fuse
B  Ceiling roses
C  Intermediate switch
D  Pendent lamp holder

30. Which is the application of DC series MCB?
A  AC motor
B  DC motor
C  Locomotives
D  Air conditioners

31. What is the term for the time taken by a fuse to interrupt the circuit in fault?
A  Time factor
B  Fusing factor
C  Cut-off factor
D  Fusing current

32. Which place the Tree system of wiring is most suitable?

A  Godown wiring
B  Industrial wiring
C  Domestic wiring
D  Multi storied building

33. What is the maximum PVC conduit size to make safe cold bending?
A  12 mm
B  19 mm
C  25 mm
D  50 mm

34. Why separate wiring is recommended for home theatre wiring and power wiring?
A  Avoid electrical fire
B  Reduce power loss
C  Avoid electrical interference
D  Maintain voltage level constant

35. What is the name of the lighting circuit?
A  Tunnel lighting wiring
B  Corridor lighting wiring
C  Godown lighting wiring
D  Staircase lighting wiring

36. What is the tool used to bend conduits?
A  Hickey
B  Coupler
C  Pipe vice
D  Bench vice

37. What is the expansion of MCB?

A  Minute Control Breaker
B  Miniature Circuit Breaker
C  Minimum Current Breaker
D  Maximum Current Breaker

38. What is the purpose of ELCB?
A  Detects the fault in circuit
B  Monitors the residual current
C  Protects the equipment from over load
D  Protects from short circuit fault

39. What is the purpose of the fuse cut out provided at the incoming power supply?
A  To ensure the line is not over loaded
B  To maintain the stabilised supply voltage
C  To protect the circuit from the leakage current
D  To protect the human beings from electric shock

40. What is the use of die stock set?
A  Cut external threads on square pipe
B  Cut internal threads on cylindrical pipe
C  Cut external threads on cylindrical pipe
D  Cut internal threads on rectangular pipe

41. Which classification of accessory the ceiling rose is classified?
A  Outlet accessories
B  Safety accessories
C  Holding accessories
D  General accessories

42. What is the purpose of the circuit diagram in wiring installation?
A  To show the physical position of accessories
B  To estimate the various accessories in the circuit
C  To inform the reader quickly what for the circuit is designed
D  To show the schematic connection of the circuit for a specific task

43. Which electrical equipment is provided with L series MCB?
A  General lighting
B  Motors
C  Air conditioner
D  Halogen lamp

44. Why the looping-back (loop in) method is preferred in domestic wiring installation?
A  Easy to identify the faults
B  No separate joints are used
C  More number of tappings can be taken
D  More number of sub-circuits can be made

45. What does the symbol marked X indicate?
A  Number of wires run on the limb
B  Number of switches to be connected
C  Number of battern (or) pipe to be fixed
D  Number of clamps (or) clips to be fixed

46. What is the name of wiring method?
A  Joint box method
B  Looping back method
C  Loop in method using 3 plate ceiling rose
D  Loop in method using 2 plate ceiling rose

47. What is the name of the diagram?
A  Staircase wiring
B  Godown wiring
C  Hostel wiring
D  Tunnel wiring

48. What is the type of relay?
A  Impulse relay
B  Dry reed relay
C  Latching relay
D  Electromagnetic relay

49. Calculate the earth fault loop impedance, if the ELCB tripping current is 30 mA?
A  166 ohm
B  1666
C  16.66
D  16666

50. What is the type of wiring?
A  CTS wiring
B  Cleat wiring
C  PVC conduit wiring
D  PVC casing and capping wiring

51. What is length of thread on rigid conduits as per BIS?
A  9mm - 20mm
B  11mm - 27mm
C  13mm - 25mm
D  15mm - 30mm

52. Which type of conduit used for gas tight explosive installation?
A  Flexible conduits
B  Rigid steel conduits
C  Rigid non-metallic conduits
D  Flexible non-metallic conduits

53. What is the function of circuit breaker?
A  Making contact at normal condition
B  Making contact at abnormal condition
C  Breaking automatically at abnormal condition
D  Physical breaking contact at abnormal condition

54. What is the function of bimetallic strip in MCB?
A  Over load protection
B  Short circuit protection
C  Over voltage protection
D  Earth leakage protection

55. What protection offered by residual current circuit breaker?
A  Protection from shock
B  Protection from over load
C  Protection from short circuit
D  Protection from leakage current

56. Which wiring is suitable for temporary installations?
A  Cleat wiring
B  Concealed wiring
C  PVC conduit wiring
D  Metal conduit wiring

57. Where the phase conductor is looped in looping system of wiring?
A  Switch box
B  Junction box
C  Distribution box
D  Socket connection

58. How many link clips are packed in cardboard boxes as per BIS rules?
A  50 clips
B  75 clips
C  100 clips
D  150 clips

59. What is the application of the wiring circuit?

A  Two lamps dim operation only
B  Two lamps controlled by one switch
C  Two lamps controlled by two switches
D  One lamp bright and two lamp dim operation

60. What is the reason for home theatre wiring not to run along with power wiring?
A  Avoid leakage current in home theatre wiring
B  Control temperature in home theatre wiring
C  Avoid electrical interference in audio, video system
D  Reduce the power consumption in power supplies

61. What will happen to the value of earth resistance if length of the earth pipe is increased?
A  Remain same
B  Increases
C  Decreases
D  Infinity

62. Which types of accessories are used to operate a portable appliance?
A  Safety accessories
B  Holding accessories
C  Outlet accessories
D  Controlling accessories

63. Which insulation is necessary for proper function and basic protection?
A  Double insulation
B  Functional insulation
C  Reinforced insulation
D  Supplementary insulation

64. Which type of accessories of fuse is comes under?
A  Controlling accessories
B  Holding accessories
C  Safety accessories
D  Outlet accessories

65. What is the expansion of ECC?
A  Earth Conductor Continuity
B  Earth Continuity Conductor
C  Earth Carrying Conductor
D  Earth Continuity Cable

66. Which type MCBs suitable for halogen lamps?
A  L series MCBs
B  G series MCBs
C  DC series MCBs
D  L and G series MCBs

67. Which type of lamp holder is used for the lamps above 300 watts?

A  Edison screw holder
B  Goliath screw holder
C  Angle holder
D  Brachet holder

68. What is the expansion of AWG?
A  American Wire Gauge
B  American Wire Grade
C  American Wire Group
D  American Wire Guard

69. What is the name of BIS symbol?
A  Lamp
B  Two way switch
C  Intermediate switch
D  Multi - position switch

70. What is the type of diagram?
A  Wiring diagram
B  Circuit diagram
C  Installation plan
D  Layout diagram